Executive Thermal Inspection Summary Report
Aerial Visual and Thermal Observations for Customer Evaluation
Report Limitation Notice
This report documents aerial visual and thermal observations collected under the conditions present at the time of inspection. Cox Aerial Solutions LLC does not diagnose electrical, structural, roofing, mechanical, or engineering conditions. Root cause, repair requirements, operating status, and maintenance decisions must be determined by the customer or its qualified personnel.
Customer Information
Customer / Utility
Prairie Valley Electric Cooperative
Project
Distribution Line Thermal Observation Documentation
Inspection Program
Annual Utility Partnership Program – Tier 3
Inspection Date
July 18, 2026
Inspection Area
Rural Distribution Circuit 14-27
Inspection Provider
Cox Aerial Solutions LLC
Inspection Platform
DJI Matrice 4T Radiometric Thermal UAS
Inspection Overview
Cox Aerial Solutions LLC completed an aerial visual and thermal inspection of the assigned distribution system utilizing FAA-compliant UAS operations, radiometric thermal imaging, and high-resolution visual documentation.
The inspection was performed to document aerial visual and thermal observations under the conditions present at the time of flight, for review by qualified customer personnel.
Inspection Coverage
| Distribution Line Inspected | 13.4 Miles |
| Utility Structures Reviewed | 126 |
| Electrical Assets Documented | 312 |
| Thermal Images Captured | 486 |
| Visual Images Captured | 512 |
| Total Observations Documented | 3 |
Overall Observation Summary
| Observation Category | Assets | Notes |
|---|---|---|
| No Elevated Observations Documented During This Inspection | 309 | No elevated thermal or visual patterns documented at time of inspection |
| Monitor | 2 | Continue observation during routine customer activities |
| Qualified Customer Evaluation Suggested | 1 | Qualified Technical Evaluation suggested |
| Elevated Priority Observations | 0 | No elevated-priority observations documented |
Documented Observation
Observation ID
CAS-PVE-2026-0718-001
Asset: Primary Distribution Connection
Structure: PV-1427-083
Circuit: 14-27
Voltage Class: 13.8 kV
Observed Condition
An elevated thermal pattern was documented at the identified component compared with nearby reference points under the conditions present at the time of inspection.
Customer Evaluation Priority
Elevated
Suggested Customer Consideration
Qualified customer personnel may review the documented area and determine whether additional testing, maintenance, monitoring, or no action is appropriate.
Maximum Recorded Temperature: 147°F
Temperature Differential: +65°F above nearby reference points
Suggested Areas for Customer Evaluation
The documented observation may warrant evaluation by qualified customer personnel. Considerations that customer personnel may choose to review include:
- ✓Ground-level review of connection hardware by qualified personnel
- ✓Customer-determined verification of connection integrity
- ✓Customer review for corrosion or deterioration
- ✓Customer-Determined Action as deemed appropriate by qualified personnel
Customer Evaluation Priority: Elevated
Observation-Based Follow-Up Considerations
Continued periodic inspection cycles may support historical documentation of asset conditions for customer review over time.
Suggested documentation approach:
- ✓Periodic aerial thermal inspection cycles
- ✓Repeat asset visual comparisons
- ✓Observation tracking of previously documented equipment
- ✓Customer-directed planning based on documented observations
Report Conclusion
No elevated thermal or visual observations were documented in the inspected areas during the completed flight operation, except where specifically identified in this report. This statement reflects conditions visible or measurable at the time of inspection and does not certify equipment condition, continued performance, code compliance, electrical integrity, structural integrity, or the absence of concealed defects.
Report findings are observation-based and are provided for customer evaluation. Cox Aerial Solutions LLC does not certify equipment condition or prescribe maintenance or repair actions.
Cox Aerial Solutions LLC
Professional Aerial Solutions Built on Safety, Precision, and Integrity
Report Number: CAS-PVE-2026-0718-001
Prepared For: Prairie Valley Electric Cooperative
Prepared By: Cox Aerial Solutions LLC